Driver Version - (read-only) The driver version currently loaded.
DALI Address - (read-only) The DALI address of the device (64-128 for instances).
Number of Buttons - (read-only) The number of button instances on this device.
Instance Type - (read-only) The DALI instance type (e.g. Push Button Part 301).
Product Name - (read-only) The product name derived from the device's EAN/GTIN code.
EAN - (read-only) The European Article Number of the device.
Serial Number - (read-only) The device serial number.
Operating Mode - (read-only) The DALI operating mode reported by the device.
Bus Unit Config - (read-only) The DALI bus unit configuration.
Automatic LED Sync - Disabled by default. When enabled, a Control4 MATCH_LED_STATE command will set the physical LED state on a button. This is useful for making the button LED reflect whether a Control4 scene is active. By default button LEDs are controlled by the zencontrol controller, and care should be taken to prevent the two systems from conflicting.
Sync - Configure the synchronisation strategy.
All - (default) Synchronise everything.
Label and Status - only update the device label and status data.
Disabled - do not synchronise this Control4 device with the controller.
Log Level - Configure the level of logging data produced by the driver.
Comments